LIVE · 2.4 MW Demand
--:--:-- CAT
EM
๐Ÿ”ด
Crushing Plant Over Limit: Drawing 650 kW vs 600 kW limit. Check motor load immediately.
๐ŸŸก
Diesel Generator Active: Running unnecessarily during peak solar hours. Switch to solar + bio.
Total Generation
4.82MW
▲ +0.3 MW vs yesterday
Target: 2.4 MW demand
Total Consumption
2.38MW
▼ Under demand budget
2,400 kW budgeted
Energy Losses
240kW
▲ +40 kW vs avg
4.9% of generation
Battery SoC
74%
Charging +0.3 MW
~5.8 hrs full runtime
Efficiency Score
82/ 100
↑ Improvable
Diesel drag −8 pts
⚡ Live Generation Sources
โ˜€๏ธ
Solar Plant
3.24 MW
5 MW rated64.8%
● GENERATING
๐ŸŒฟ
Bio Generator
1.28 MW
2 MW rated64%
● ONLINE
๐Ÿ”‹
Battery Storage
0.00 MW
74% SoCCharging
● CHARGING
โ›ฝ
Diesel Backup
0.30 MW
2 MW rated15%
⚠ AVOID
Energy Flow Diagram
Generation → Storage → Mine Equipment (real-time)
● LIVE
โ˜€๏ธ
Solar
3.24 MW
๐ŸŒฟ
Bio Gen
1.28 MW
โ›ฝ
Diesel
300 kW
AC Bus
4.82 MW
2.38 MW to mine
๐Ÿ”‹
Battery
74% SoC
๐Ÿ—๏ธ
Crushing
650 kW
โš™๏ธ
Ball Mill
850 kW
๐Ÿ’จ
Ventilation
380 kW
Demand vs Supply Balance
Real-time generation meeting mine load
โ˜€๏ธ Solar3.24 MW
๐ŸŒฟ Bio Generator1.28 MW
โ›ฝ Diesel0.30 MW
⚡ Mine Consumption2.38 / 2.4 MW
2.38 MW — 99.2%
Surplus: 2.44 MW → Battery charging
Source Switching Priority
AI-recommended dispatch order
1
โ˜€๏ธ Solar Plant
Zero marginal cost · 3.24 MW available
ACTIVE
2
๐ŸŒฟ Bio Generator
Low cost · 1.28 MW · waste fuel
ACTIVE
3
๐Ÿ”‹ Battery Storage
Dispatch on deficit · 74% SoC
STANDBY
4
โ›ฝ Diesel Generator
โš  Running — not needed right now
SHUT DOWN
๐Ÿญ Equipment Energy Consumption
โš™๏ธ Ball Mill / Grinding — 24-Hour Consumption
Click any equipment row below to switch view · hover chart for exact reading
● LIVE
0
LIMIT NOW
Consumption
Limit
Peak Today
Avg Today
Right Now
MWh Today
Mining Equipment Monitor
ⓘ Click any row to view 24-hour consumption chart above · hover chart for exact reading per hour
EquipmentLive DrawLimitLoad %Today 0–24h (Sparkline)VibrationTempRuntimeStatusAction
Energy Loss Detection
Generation − Consumption = Losses & Leaks
4.82 MW
Generated
2.38 MW
Consumed
240 kW
Losses
Crushing Plant over-draw
50 kW
Inverter conversion losses
82 kW
Cable / distribution losses
61 kW
Vent fan inefficiency
47 kW
Standby / auxiliary loads
~30 kW
Battery Storage System
SoC · charge rate · runtime estimate
State of Charge
74%
Charge Rate+0.30 MW (Charging)
Discharge Capacity2.0 MW max
Runtime at Full Load~40 min
Runtime at 1 MW Load~5.8 hours
Cell Temperature28.4°C
BMS StatusHealthy
Cycle Count1,204 / ~4,000
Daily Energy Analytics
Last 7 days · click tabs to switch view
System Efficiency Score
Composite performance rating
82
/ 100
Solar Utilisation94%
Bio Efficiency78%
Battery Round-trip92%
Diesel Penalty−8 pts
Equipment Avg Eff.89%
๐Ÿ”” Active Alerts
Critical
2 ACTIVE
Crushing Plant Over Limit
Drawing 650 kW vs 600 kW limit. Motor thermal risk.
4 min ago
Diesel Running Unnecessarily
300 kW diesel during peak solar. ZMW 2,800/hr wasted.
12 min ago
Warnings
2 ACTIVE
Ball Mill Vibration High
4.8 mm/s on bearing 3. Schedule inspection.
27 min ago
Solar Below Forecast
3.24 vs 3.8 MW expected. Panel soiling likely.
1 hr ago
Info
1 NOTICE
Bio Generator Heat Recovery
Hot water temp: 74°C. Flow rate: 12 L/min. Optimal.
2 hrs ago
๐Ÿ“ก IoT Device Status
โšก
● Online
Smart Energy Meters
Schneider PowerLogic · 18 units
4.82 MW
Total Gen
0.96 PF
Power Factor
415 V
Voltage
17/18
Online
โ˜€๏ธ
● Online
Solar Inverter Telemetry
SMA Sunny Tripower · 5 MW array
3.24 MW
Output
84%
Efficiency
620 W/m²
Irradiance
Soiling
Alert
๐ŸŒฟ
● Online
Bio Generator Sensors
Temp + Flow + Pressure · 6 sensors
1.28 MW
Output
74°C
Hot Water
12 L/min
Flow Rate
Normal
Pressure
๐Ÿ”‹
● Online
Battery BMS
Victron MultiPlus-II · 2 MWh bank
74%
SoC
+0.3 MW
Charge Rate
28.4°C
Temp
Healthy
BMS
โ›ฝ
โš  Active
Diesel Generator
Cummins C2000D5 · 2 MW rated
300 kW
Output
3.4 L/hr
Fuel Rate
68%
Tank Level
Avoid
Status
๐ŸŒก๏ธ
โš  Alert
Vibration & Temp Sensors
SKF CMSS 793 · 24 motors
4.8 mm/s
Vibration
78°C
Max Temp
23/24
Online
1 Alert
Issues
๐Ÿ’จ
● Online
Ventilation Sensors
Honeywell MIDAS · 8 zones
6/8
Active Zones
16 ppm
CO² Avg
380 kW
Fan Load
Safe
Air Quality
๐Ÿ“ก
● Online
IoT Edge Gateways
Sierra Wireless RV55 · 3 units
4G LTE
Connection
MQTT
Protocol
3/3
Online
9 sec
Last Sync
Data Integration Protocols
Supported real-time ingestion methods · all active
๐Ÿ“ก
MQTT Broker
Real-time sensor data · Eclipse Mosquitto
Connected
๐Ÿ”Œ
Modbus TCP
Energy meters · Inverters · Genset controllers
18 Devices
๐ŸŒ
REST API
Cloud sync · Analytics · Third-party
Active
โšก
WebSocket
Live dashboard · Sub-second latency
Live